European Association of Automotive Suppliers
5 documents
16 Mar UN R10.08: Revisiting Requirements on Harmonics in IEC 61000-3-12 (CLEPA and EMC Test NRW) EMC-50-15/Rev.1 2026-03-16 CLEPA EMC Test NRW
26 Feb Usage of the Average Detector with meter time constants as defined in CISPR 16-1-1 (CLEPA) EMC-51-02 2026-02-26 CLEPA
22 Mar Review of Different Artificial Networks in UN R10 (CLEPA) EMC-51-08 2026-03-22 CLEPA
26 Jun Standardized testing conditions for harmonics and flicker vs. actual grid connection (CLEPA) EMC-53-08 2026-06-26 CLEPA proposes standardized testing conditions for harmonics and flicker in UN R10 across countries with differing grid voltages and frequencies. Three cases are presented: Case 1 applies requirements to 220–240 V single-phase or 380–415 V three-phase at 50 or 60 Hz only; Case 2 permits multi-voltage operation but tests only at 220–240 V or 380–415 V; Case 3 applies scaled limits for region-specific operation at different voltages such as 100 V, with IEC 61000-3-3 and IEC 61000-3-11 marked not applicable due to impedance specifications limited to 220–250 V systems. CLEPA
1 Sep Clarification of the Observation Time for Harmonics Measurement (OICA and CLEPA) EMC-54-02 2026-09-01 Proposal to amend Annexes 11 and 17 to specify an observation time of 2.5 min for quasi-stationary equipment as defined in Table 4 of IEC 61000-3-2, with the equipment operating in the mode expected to produce the maximum total harmonic current under normal operating conditions. Currently, UN R10.07 does not specify an observation time, which may lead to different interpretations of the test method and case-by-case agreement during type approval. Specifying 2.5 min would provide a consistent observation and averaging period for vehicle and ESA type-approval tests without changing existing test conditions, limits, or evaluation method. OICA CLEPA