| UN R100: Proposal for a new Supplement to the 05 series of amendments |
| Reference Number: GRSP-80-09 |
|
Proposal to replace the heating rate requirement of ≥15 °C/s with ≥10 °C/s in Annex 9K Appendix 1 Table 1, and insert new Annex 9K Appendix 1bis setting out the Thermal Runaway Trigger Method with a Localized Rapid Heater within the cell casing. The new appendix specifies preparation of the tested-device, selection guide for the heater element with target parameters including material, thickness, area, heating rate, maximum temperature and control method, test procedures for vehicle-based testing, and test procedures for component-based testing. |
| Submitted by: OICA |
| Meeting Sessions: 80th GRSP session (7-11 Dec) |
| Document date: 11 Nov 26 |
| Relevant to: UN Regulation No. 100 | Construction and Safety of Electric Powertrains |
| Click here to view the full document file |
| UN R100: Request for comment on the proposals to streamline the provisions |
| Reference Number: GRSP-80-07 |
|
OICA requests comments from GRSP experts on proposals for streamlining UN R100, following presentations at the 79th session. Working documents ECE/TRANS/WP.29/GRSP/2026/25 and ECE/TRANS/WP.29/GRSP/2026/26 were released on 14 October in English only. Comments should be submitted using the template in informal document GRSP-80-07-Add.1 to facilitate consolidation of feedback and identify discussion points toward the 80th session. |
| Submitted by: OICA |
| Meeting Sessions: 80th GRSP session (7-11 Dec) |
| Document date: 09 Nov 26 |
| Relevant to: UN Regulation No. 100 | Construction and Safety of Electric Powertrains |
| Click here to view the full document file |
| UN R100: Form for comments on streamlining proposals |
| Reference Number: GRSP-80-07-Add.1 |
| Submitted by: OICA |
| Meeting Sessions: 80th GRSP session (7-11 Dec) |
| Document date: 09 Nov 26 |
| Relevant to: UN Regulation No. 100 | Construction and Safety of Electric Powertrains |
| Click here to view the full document file |
| UN R135: Proposal for a Supplement 4 to the original text, a Supplement 5 to the 01 series, and a Supplement 5 to the 02 series of amendments |
| Reference Number: GRSP-80-06 |
|
Proposal to insert a new section 0 to clarify the direction of the force applied to verify that the door has not been opened during the test, and amend para. 5.4.2.1. to specify that the door does not open under a static tractive force of at least 400 N in the y-direction applied to the door as close as possible to the window sill and to the edge of the door opposite to the hinged side, except to the door handle itself. |
| Submitted by: Spain |
| Meeting Sessions: 80th GRSP session (7-11 Dec) |
| Document date: 30 Oct 26 |
| Relevant to: UN Regulation No. 135 | Pole side-impact protection |
| Click here to view the full document file |
| UN R95: Proposal for a Supplement 4 to the 04 series, a Supplement 6 to the 05 series, and a Supplement 4 to the 06 series of amendments |
| Reference Number: GRSP-80-05 |
|
Proposal to amend para. 5.3.1. to clarify the direction of the force applied to verify that the door has not been opened during the test. The requirement is deemed fulfilled if the door does not open under a static tractive force of at least 400 N in the y-direction applied to the door, as close as possible to the window sill and to the edge of the door opposite to the hinged side, except to the door handle itself. This clarification applies to all different types of doors, including doors which open vertically or sliding doors. |
| Submitted by: Spain |
| Meeting Sessions: 80th GRSP session (7-11 Dec) |
| Document date: 30 Oct 26 |
| Relevant to: UN Regulation No. 95 | Occupant Protection in Lateral Collisions |
| Click here to view the full document file |