26 Mar 2012
|
Incorporation of Standardised Replaceable LED Light Sources into UN Regulations (GTB)
|
GRE-67-24
|
2012-03-26 |
The Forum adopted a new UN Regulation on LED light sources at its March 2012 session. This document updates the collective amendment that introduces LED light sources into the relevant UN Regulations 4, 6, 7, 23, 38, 50, 77, 87, 91 and 119. GTB |
|
20 Sep 2012
|
Proposal for editorial correction to document GRE/2012/42 (GTB)
|
GRE-68-02
|
2012-09-20 |
GTB proposal to amend the geometric visibility provisions. Subsequent to the preparation of the proposed amendments in document GRE/2012/42, several editorial corrections have been identified by GTB experts. This document replaces that original submission. GTB |
|
18 Oct 2012
|
Proposal for editorial correction to document GRE/2012/42 (GTB)
|
GRE-68-02/Rev.1
|
2012-10-18 |
GRE/2012/42 is a GTB proposal to amend the geometric visibility provisions. This document corrects GRE/2012/42 in line with the latest state of the subject regulations including amendments submitted for consideration at the November WP.29 session. GTB |
|
7 Nov 2012
|
Proposal for editorial correction to document GRE/2012/42 (GTB)
|
GRE-68-02/Rev.2
|
2012-11-07 |
This document contains editorial corrections to document GRE/2012/42 to amend the geometric visibility provisions of Regulations No. 3, 6, 7, 48, 77 and 91 following a review with the GRE secretariat to ensure that the proposal aligns with the latest state of the regulations. GTB |
|
11 Sep 2013
|
Proposal for corrections to document GRE/2013/45 (GTB)
|
GRE-70-02
|
2013-09-11 |
Recommended corrections to the proposal to clarify the definition of "type" with regard to manufacturer, trade names and marks as used in Regulations Nos. 4, 6, 7, 19, 23, 38, 45, 50, 77, 87, 91,98 ,104, 112, 113, 119 and 123. GTB |
|
18 Oct 2016
|
Correction to document GRE/2016/31 (GTB)
|
GRE-76-07
|
2016-10-18 |
Correction to the proposal for a collective amendment to Regulations Nos. 7, 23, 38, 48, 77, 91 and 119. Since the cornering lamp projects a beam to the left and right of the reference axis, it is not relevant to check the photometric values in the reference axis (HV). Therefore, the test point at 2.5°D, 45°L or R shall be used. GTB |
|
27 Oct 2016
|
Revision of document ECE/TRANS/WP.29/GRE/2016/31 (GTB)
|
GRE-76-22/Rev.1
|
2016-10-27 |
Revised proposal (removing the section on UN R48 and incorporating corrections noted in document GRE-76-07) to refine the requirements for lamps equipped with several light sources, including in systems fitted with an operating tell-tale that indicates the failure of any one of these light sources. In the case of failure of any one light source in a single lamp containing more than one light source, either the light intensity must comply with the minimum intensity required in the table of standard light distribution in space or, for lamps used in systems where a tell-tale indicates the failure of any one of the light sources, the light intensity in the axis of reference must be at least 50 per cent of the minimum intensity required. This collective amendment addresses Regulations Nos. 7, 23, 38, 77, 91 and 119. The proposals concerning UN R48 will be resubmitted for consideration during the 77th GRE session. GTB |
|
14 Jan 2010
|
Collective amendments to Regulations Nos. 3, 4, 6, 7, 19, 23, 27, 31, 38, 45, 50, 65, 69, 70, 77, 87, 88, 91, 98, 104, 112, 113, 119 and 123 (GTB)
|
GRE/2010/3
|
2010-01-14 |
Proposal to clarify the definitions of type with regard to manufacturer, trade names and marks.
GTB |
|
13 Jan 2011
|
Proposal for Supplement 15 to Regulation No. 77 (GTB)
|
GRE/2011/12
|
2011-01-13 |
GTB |
|
30 Aug 2012
|
Proposal for collective amendments to Regulations Nos. 3, 6, 7, 48, 77 and 91 (GTB)
|
GRE/2012/42
|
2012-08-30 |
Proposal from the Working Party “Brussels 1952” (GTB) to amend the geometric visibility provisions. GTB |
|
14 Aug 2013
|
Proposal for Collective amendments to Regulations Nos. 4, 6, 7, 19, 23, 38, 45, 50, 77, 87, 91,98 ,104, 112, 113, 119 and 123 (GTB)
|
GRE/2013/45
|
2013-08-14 |
Proposal to clarify the definition of "type" with regard to manufacturer, trade names and marks. GTB |
|
20 Jan 2014
|
Proposal for Collective amendments to Regulations Nos. 4, 6, 7, 19, 23, 38, 45, 50, 65, 77, 87, 91, 98, 104, 112, 113, 119 and 123 (GTB)
|
GRE/2014/3
|
2014-01-20 |
Text prepared by the International Automotive Lighting and Light Signalling Expert Group (GTB) to clarify the definition of "type", with regard to manufacturer, trade names and marks and to introduce editorial improvements to the requirements for markings.
Although documents GRE/2013/45 and GRE-70-02 were adopted by GRE at its last (70th) session, this proposal consolidates the amendments and offers editorial improvements to the provisions concerning markings in Regulations Nos. 19, 23, 38, 65 and 119. These editorial improvements aim to clarify that the devices, and not only the samples, shall bear the trade name or mark and align the requirements with the other correctly worded regulations to avoid misunderstanding.
GTB |
|
28 Jan 2015
|
Proposal for Supplement 17 to Regulation No. 77 (GTB)
|
GRE/2015/12
|
2015-01-28 |
This proposal concerns lamps equipped with several light sources and fitted with an operating tell-tale that indicates the failure of any one of these light sources. The current provisions for the failure of one light source (the “N-1” requirement) are difficult to apply as a complete photometric check for all possible combinations of light source failure is required. The revised text follows the approach of supplement 17 to Regulation No. 87 and removes the requirement to check the complete photometric requirement, in case of failure of any light source, when the lamp is fitted on the vehicle with an operating tell-tale. GTB |
|
21 Jan 2016
|
Proposal for collective amendments to Regulations No. 7, 23, 38, 77, 91, and 119 (GTB)
|
GRE/2016/13
|
2016-01-21 |
Proposal to refine the requirements for lamps equipped with several light sources, including in systems fitted with an operating tell-tale that indicates the failure of any one of these light sources. In the case of failure of any one light source in a single lamp containing more than one light source, either the light intensity must comply with the minimum intensity required in the table of standard light distribution in space or, for lamps used in systems where a tell-tale indicates the failure of any one of the light sources, the light intensity in the axis of reference must be at least 50 per cent of the minimum intensity required. GTB |
|
12 Aug 2016
|
Proposal for a collective amendment to Regulations Nos. 4, 6, 7, 23, 38, 50, 77, 87, 91 and 119 (GTB)
|
GRE/2016/30
|
2016-08-12 |
This proposal removes the requirement to indicate the rated wattage in the marking of lamps equipped with electronic light source control gear and/or non-replaceable light sources and/or light source module(s). From an electronic point of view, the information of the wattage brings no benefit and is confusing if the same module is used in different systems and at different wattages. GTB |
|
17 Aug 2016
|
Proposal for a collective amendment to Regulations Nos. 7, 23, 38, 48, 77, 91 and 119 (GTB)
|
GRE/2016/31
|
2016-08-17 |
The current requirements on light source failure in lamps equipped with multiple light sources differ across UN Regulations. GTB submitted and then withdrew a proposal to align these requirements (GRE/2016/13). This updated proposal improves upon the text of the previous proposal to refine the requirements for lamps equipped with several light sources, including in systems fitted with an operating tell-tale that indicates the failure of any one of these light sources. In the case of failure of any one light source in a single lamp containing more than one light source, either the light intensity must comply with the minimum intensity required in the table of standard light distribution in space or, for lamps used in systems where a tell-tale indicates the failure of any one of the light sources, the light intensity in the axis of reference must be at least 50 per cent of the minimum intensity required. GTB |