| previous agenda item | next agenda item |
|
25. Progress update of this project was given by Francesco Riccobono (JRC). |
|
|
26. Stability of the aerosol (thermal) for calibration: In considering the aerosols most similar to soot, it was found that the counting efficiency variation due to material dependency was in same order of magnitude as the measurements – soot-like” seems not to be a good criteria to select the standard aerosol, although need for harmonisation remains. |
|
|
27. The next experimental setup will be to test many silver (Ag) generators; note silver is the furthest away from today’s materials …. This has implications on pass / fail of measurement results. CAST generators optimised for small size are quite similar now and should be compared to silver. |
|
|
28. EMRP will finish in 2014. Feb 2014 meeting will discuss next steps and recommendations. For more information, see the EMRP website. |
|
|
29. JRC also provided an update on periodic emission control metrological validation – see also (GRPE-PMP-28-05) – 7 instruments reviewed and tested. Research on-going for instruments to replace todays opacimeters – instruments evaluated show large variability at low PN / mass conc. and sizes. |
PMP-28-05 | Emerging requirements for measuring pollutants from automotive exhaust emissions
|