| Revision of document ECE/TRANS/WP.29/GRE/2016/31 |
| Reference Number: GRE-76-22/Rev.1 |
|
Revised proposal (removing the section on UN R48 and incorporating corrections noted in document GRE-76-07) to refine the requirements for lamps equipped with several light sources, including in systems fitted with an operating tell-tale that indicates the failure of any one of these light sources. In the case of failure of any one light source in a single lamp containing more than one light source, either the light intensity must comply with the minimum intensity required in the table of standard light distribution in space or, for lamps used in systems where a tell-tale indicates the failure of any one of the light sources, the light intensity in the axis of reference must be at least 50 per cent of the minimum intensity required. This collective amendment addresses Regulations Nos. 7, 23, 38, 77, 91 and 119. The proposals concerning UN R48 will be resubmitted for consideration during the 77th GRE session. |
| Submitted by: GTB |
| Meeting Sessions: 76th GRE session (25-28 Oct 2016) |
| Document date: 26 Oct 16 |
| Document status: Superseded |
|
Relevant to
UN Regulation No. 7 | Position, Stop and End-outline Lamps, UN Regulation No. 23 | Reversing Lights, UN Regulation No. 38 | Rear Fog Lamps, UN Regulation No. 48 | Installation of Lighting and Lighting-Signalling Equipment, UN Regulation No. 77 | Parking Lamps, UN Regulation No. 91 | Side-Marker Lamps, and UN Regulation No. 119 | Cornering Lamps
|
| View full document file for more information |
| Correction to document GRE/2016/31 |
| Reference Number: GRE-76-07 |
|
Correction to the proposal for a collective amendment to Regulations Nos. 7, 23, 38, 48, 77, 91 and 119. Since the cornering lamp projects a beam to the left and right of the reference axis, it is not relevant to check the photometric values in the reference axis (HV). Therefore, the test point at 2.5°D, 45°L or R shall be used. |
| Submitted by: GTB |
| Meeting Sessions: 76th GRE session (25-28 Oct 2016) |
| Document date: 17 Oct 16 |
| Document status: Superseded |
|
Relevant to
UN Regulation No. 7 | Position, Stop and End-outline Lamps, UN Regulation No. 23 | Reversing Lights, UN Regulation No. 38 | Rear Fog Lamps, UN Regulation No. 48 | Installation of Lighting and Lighting-Signalling Equipment, UN Regulation No. 77 | Parking Lamps, UN Regulation No. 91 | Side-Marker Lamps, and UN Regulation No. 119 | Cornering Lamps
|
| View full document file for more information |
| Proposal for a collective amendment to Regulations Nos. 7, 23, 38, 48, 77, 91 and 119 |
| Reference Number: GRE/2016/31 |
|
The current requirements on light source failure in lamps equipped with multiple light sources differ across UN Regulations. GTB submitted and then withdrew a proposal to align these requirements (GRE/2016/13). This updated proposal improves upon the text of the previous proposal to refine the requirements for lamps equipped with several light sources, including in systems fitted with an operating tell-tale that indicates the failure of any one of these light sources. In the case of failure of any one light source in a single lamp containing more than one light source, either the light intensity must comply with the minimum intensity required in the table of standard light distribution in space or, for lamps used in systems where a tell-tale indicates the failure of any one of the light sources, the light intensity in the axis of reference must be at least 50 per cent of the minimum intensity required. |
| Submitted by: GTB |
| Meeting Sessions: 76th GRE session (25-28 Oct 2016) |
| Document date: 12 Aug 16 |
| Document status: Superseded |
|
Relevant to
UN Regulation No. 7 | Position, Stop and End-outline Lamps, UN Regulation No. 23 | Reversing Lights, UN Regulation No. 38 | Rear Fog Lamps, UN Regulation No. 48 | Installation of Lighting and Lighting-Signalling Equipment, UN Regulation No. 77 | Parking Lamps, UN Regulation No. 91 | Side-Marker Lamps, and UN Regulation No. 119 | Cornering Lamps
|
| View full document file for more information |
| Proposal for a collective amendment to Regulations Nos. 4, 6, 7, 23, 38, 50, 77, 87, 91 and 119 |
| Reference Number: GRE/2016/30 |
|
This proposal removes the requirement to indicate the rated wattage in the marking of lamps equipped with electronic light source control gear and/or non-replaceable light sources and/or light source module(s). From an electronic point of view, the information of the wattage brings no benefit and is confusing if the same module is used in different systems and at different wattages. |
| Submitted by: GTB |
| Meeting Sessions: 76th GRE session (25-28 Oct 2016) |
| Document date: 11 Aug 16 |
| Document status: Superseded |
|
Relevant to
UN Regulation No. 4 | Illumination of rear-registration plates of motor vehicles and their trailers, UN Regulation No. 6 | Direction Indicators, UN Regulation No. 7 | Position, Stop and End-outline Lamps, UN Regulation No. 23 | Reversing Lights, UN Regulation No. 38 | Rear Fog Lamps, UN Regulation No. 50 | Position and Indicator Lamps for Motorcycles, UN Regulation No. 77 | Parking Lamps, UN Regulation No. 87 | Daytime Running Lamps, UN Regulation No. 91 | Side-Marker Lamps, and UN Regulation No. 119 | Cornering Lamps
|
| View full document file for more information |
| Proposal for collective amendments to Regulations No. 7, 23, 38, 77, 91, and 119 |
| Reference Number: GRE/2016/13 |
|
Proposal to refine the requirements for lamps equipped with several light sources, including in systems fitted with an operating tell-tale that indicates the failure of any one of these light sources. In the case of failure of any one light source in a single lamp containing more than one light source, either the light intensity must comply with the minimum intensity required in the table of standard light distribution in space or, for lamps used in systems where a tell-tale indicates the failure of any one of the light sources, the light intensity in the axis of reference must be at least 50 per cent of the minimum intensity required. |
| Submitted by: GTB |
| Meeting Sessions: 75th GRE session (5-8 Apr 2016) |
| Document date: 21 Jan 16 |
| Document status: Withdrawn |
|
Relevant to
|
| View full document file for more information |
No matching documents.