Proposal to require an exterior protection on cylindrical gas tanks. Under the current regulation, such exterior protection may be fitted at the discretion of the manufacturer. The intention is to increase protection against corrosion of cylinders in response to a corroded cylinder explosion in Germany.
41. The expert from the Netherlands introduced ECE/TRANS/WP.29/GRSG/2015/6 proposing new provisions on a directional discharge of the pressure relief devices for Compressed Natural Gas (CNG) containers. The expert from Germany presented GRSG-108-08 proposing a number of improvements to the proposed text. Following the discussion, GRSG noted a general support on the final proposal as reflected in GRSG-108-08-Rev.2.
42. GRSG adopted ECE/TRANS/WP.29/GRSG/2015/6 as amended by Annex IV to this report. The secretariat was requested to submit the adopted proposal to WP.29 and AC.1 for consideration at their November 2015 sessions, as draft 02 series of amendments to UN Regulation No. 110.
35. The expert from Germany withdrew GRSG-105-31. He presented GRSG-106-27 requiring the mandatory exterior protection of gas cylinders instead of leaving the decision up to the manufacturer. The experts from France and OICA preferred to adopt such mandatory provisions together with a set of transitional provisions. GRSG agreed to resume consideration at its next session in October 2014, on the basis of a revised proposal by the expert from Germany.
GRSG-106-27 |