PMP-30-10
Volatile Particle Remover Calibration and Validation Procedures
Source(s)
AEA
Date
3 Apr 2014
Status
Subject
Meeting(s)

This document describes the calibration and validation procedures for the VPR. Calibration of the VPR is to be performed at the point of manufacture and validation is to be performed at least at 6 month intervals for all instruments without automatic temperature sensors or at least at 12 month intervals if automatic temperature sensors are present. The calibration procedure must be repeated if the system ‘fails’ its validation procedure or the particle number measurement system is modified in any way.

UNECE server
Excerpts from session reports
PMP | Session 30 | 3-4 Apr 2014

The VPR calibration report is currently unchanged – the recommendations from JRC were added to the report as comments .

The CPC calibration document is also unchanged.

Both documents to be uploaded to PMP website with request for comments.

Agreed – only to consider updates in relation to 23nm at the present time. A further update to 10nm would be made when more information is available.

Next meeting – BERN GPF presentation