| Document title | Korea comments on the VIAQ informal group work items | ||||||||||
| Date | 22 Oct 2016 | ||||||||||
| Source(s) | Korea | ||||||||||
| Status | |||||||||||
| Rulemaking area(s) | |||||||||||
| Meeting(s) | |||||||||||
| Related documents | |||||||||||
| Downloads: | .pdf format | ||||||||||
| Excerpts from session reports related to this document | |||||||||||
| VIAQ | Session 6 | 25-26 Oct 2016 |
3.1 Task from 5th meeting: Comments on test temperature ambient mode 23° or 25°C Dr. Lee on behalf of Korea gave a presentation on VIAQ measurement results at 23°C and 25°C. Measured values for VOCs and Aldehydes were very similar at both temperatures. Acetaldehyde and Formaldehyde were slightly higher at 25°C. The expert from Korea concluded that ambient test temperature can be set to 23°C or 25°C. Korea would prefer testing at 25°C, but won’t oppose 23°C (VIAQ-06-09). Dr. Bulycheva on behalf of Russia said that 23°C test temperature is more relevant for Russia, but won’t oppose a compromise. Prof. Ge on behalf of China suggested a compromise of testing temperature from 23,0-25,0°C. Dr. Kovacs on behalf of OICA said that OICA is in favour of 23°C test temperature, but won’t oppose on a test temperature of 25°C. However, OICA temperature deviation at 25°C [then] has to be limited to +/- 0,5°C. The group concluded on the compromise of China for an ambient test temperature from 23,0-25,0°C, recommended to be as close as possible to 25.0 °C, and closed this working item. |
||||||||||