| Other documents |
GRSP-60-24 | Authorization to develop Phase 2 of GTR No. 13
|
Authorization to develop Phase 2 of GTR No. 13
|
|
Reference Number: GRSP-60-24
|
|
Draft proposal for eventual submission to WP.29 for the further development of the GTR on hydrogen fuel-cell vehicle safety, including the following additional areas for consideration: - Scope revision to address additional vehicle classes;
- Requirements for material compatibility and hydrogen embrittlement;
- Requirements for the fuelling receptacle;
- Evaluation of performance-based test for long-term stress rupture proposed in Phase 1;
- Consideration of research results reported after completion of Phase 1 – specifically research related to electrical safety, hydrogen storage systems, and post-crash safety;
- Consideration of 200 per cent NWP or lower as the minimum burst requirement;
- Safety guard system for the case of isolation resistance breakdown.
|
|
Submitted by: EC, Japan, and Korea
|
|
Meeting Sessions: 60th GRSP session (13-16
Dec 2016)
|
|
Document date: 15 Dec 16
|
|
Document status: Superseded
|
|
Relevant to
|
|
View full document file for more information
|
WP.29/2017/56 | Proposal for authorization to develop Phase 2 of GTR No. 13
|
Proposal for authorization to develop Phase 2 of GTR No. 13
|
|
Reference Number: WP.29/2017/56
|
|
Proposal for the Phase 2 development of GTR No. 13, including - Further consideration of items in the original authorization (document WP.29/AC.3/17);
- Potential revision of the scope to address additional vehicle classes;
- Requirements for material compatibility and hydrogen embrittlement;
- Requirements for the fueling receptacle;
- Evaluation of performance-based test for long-term stress rupture proposed in Phase 1 (including assessment of a procedure to evaluate the risk of long-term stress rupture of storage containers made from composite fiber reinforced polymers);
- Consideration of research results reported after completion of Phase 1 – specifically research related to electrical safety, hydrogen storage systems, and post-crash safety;
- Consideration of 200 per cent Nominal Working Pressure (NWP) or lower as the minimum burst requirement; and
- Consider Safety guard system for the case of isolation resistance breakdown.
|
|
Submitted by: EU, Japan, and Korea
|
|
Meeting Sessions: 171st WP.29 session (14-17
Mar 2017)
|
|
Document date: 22 Dec 16
|
|
Document status: Mandate approved
|
|
Relevant to
|
|
View full document file for more information
|
|