33. The expert from GTB withdrew their proposal to update the provisions on failure of light sources when a tell-tale indicating failure is installed (ECE/TRANS/WP.29/GRE/2016/13).
Documentation
GRE/2016/13
Proposal for collective amendments to Regulations No. 7, 23, 38, 77, 91, and 119 (GTB)
Proposal for collective amendments to Regulations No. 7, 23, 38, 77, 91, and 119
Proposal to refine the requirements for lamps equipped with several light sources, including in systems fitted with an operating tell-tale that indicates the failure of any one of these light sources. In the case of failure of any one light source in a single lamp containing more than one light source, either the light intensity must comply with the minimum intensity required in the table of standard light distribution in space or, for lamps used in systems where a tell-tale indicates the failure of any one of the light sources, the light intensity in the axis of reference must be at least 50 per cent of the minimum intensity required.
UN R7 Position, stop and end-outline lamps | UN R23 Reversing Lights | UN R38 Rear Fog Lamps | UN R77 Parking Lamps | UN R91 Side-Marker Lamps | UN R119 Cornering Lamps