EqOP-WS-05-16
A Field-Crash-Validated Female Lower Extremity Injury Criterion and Chest Injury Assessment
Source(s)
Date
5 Nov 2026
Status
Subject
Meeting(s)

Two presentations on frontal crash safety metrics. The first introduces FLEIC, a combined score based on HIII-50M measurements from femur, knee, tibia, and foot that predicts female lower extremity injury in real-world front crashes and shows better repeatability than component measures. Common sources of elevated FLEIC are dynamic toepan intrusion and knee airbag deployment. The second presents high-speed pressure mat data collected from 87 crash tests and 3 sled tests to evaluate chest loading distribution across ribs. Proposed force imbalance metrics enable comparison of force magnitude and distribution, showing sensitivity to belt and airbag configuration.