Show admin view
Flex-GTR Master Leg Development and Evaluation
Document GTR9-07-08
27 June 2013

Development of the Flex-GTR Master Leg FE Model and Evaluation of the Validity of the Current Threshold Values against the Flex-GTR Master Leg

Submitted by JASIC
Download document
Previous Documents, Discussions, and Outcomes
7.1. | Information on the different approaches to derive the injury criteria / impactor thresholds

Dr. Konosu presented document GTR9-7-08 on behalf of JASIC. JASIC developed a FlexPLI master leg FE model. Then, it was confirmed that the model has a good correlation with the human FE model. Moreover, it was found that there is no need to modify the current threshold values for the FlexPLI master leg level. Mr. Zander replied to not see a good correlation. Dr. Konosu replied that JASIC believes that the model has a good correlation. However, JASIC does not want to argue this. No further comments were received on this.

Relates to GTR No. 9 |