PMP-55.1-08
GTR 24: Changes and improvements
Downloads
UNECE server
Related documents
ILS 3 Findings and GTR 24 Updates addresses improvements to the Particle Measurement Programme. References to three-probe layout and smaller duct diameters are deleted; duct inner diameter is defined as 190–225 mm. A column defining numbers of decimals is added to Table 8.1. Bedding and emissions measurement sections shall use new parts. Temperature requirements at filter holder are clarified to remain above 15°C. Requirements on decimal places are added throughout Tables 13.1, 13.3, 13.4, 13.5, and 13.6. Table 13.6 now counts from 1 to 274. Unit notation is harmonized. Signal filtering requirements are added to Chapter 5.4. Various requests are rejected, including repositioning sampling nozzles and probes, PM₁₀ probe positioning, and OEM-declared threshold pressure values.
Global Technical Regulation
Original Equipment Manufacturer: The original vehicle manufacturer