Show admin view
Weight Increase Calculation to Change to Aluminium Hip Cups for Q3, Q1.5 and Q1
Document CRS-54-10
27 October 2015

Data to support change from plastic to aluminum hip cup in order to resolve Q-dummy problem where the plastic cup has not been strong enough to retain the hip joint (ball and socket) in position.

Download document
Previous Documents, Discussions, and Outcomes
6.4. | Humanetics Q3 presentation

HUMANETICS to provide drawings representing modifications on abdominal sensors for Q1.5 and Q3. For the Q1.5 the abdomen drawing is to be updated. For the Q3 the abdomen drawing is to be updated, the hip liner is to be added, suit modification for hip liner to be included and hip cup material change (to be decided).

Question from Paul LEMMEN (HUMANETICS): do the hip liner include in the package? For Pierre CASTAING (UTAC & Chairman): Yes, only one set of change is better and for Q3 first as we use this dummy for phase I of the R129 regulation.

Relates to UN R44 | UN R129 |