UN R134: Working draft proposal for a Supplement to the 03 series of amendments
Downloads
UNECE server
Related documents
Proposal to amend para. 2.1. to specify that an appropriate adaptor means a test component specified by the CHSS manufacturer that substitutes for the container valve, additional TPRD, and end plug, and includes an outlet with the proper fitting size and geometry to connect the supply line to the additional TPRD if applicable, with a note defining container valve and end plug, amend para. 5.1.1. to require that connections between the supply line for additional TPRDs and appropriate adaptor(s) shall meet the requirements and are within the scope of the test, amend para. 5.1.2. to require that connections between the supply line for additional TPRDs and appropriate adaptor(s) shall meet the requirements and are within the scope of the test, amend para. 5.2. to require that connections between the supply line for additional TPRDs and appropriate adaptor(s) shall meet the requirements and are within the scope of the test, and amend Annex 3 para. 5.1. to delete “through appropriate adaptors” from the requirement regarding supply lines for additional TPRDs.
Compressed Hydrogen Storage System
Thermally activated pressure relief device