Revised proposal (removing the section on UN R48 and incorporating corrections noted in document GRE-76-07) to refine the requirements for lamps equipped with several light sources, including in systems fitted with an operating tell-tale that indicates the failure of any one of these light sources. In the case of failure of any one light source in a single lamp containing more than one light source, either the light intensity must comply with the minimum intensity required in the table of standard light distribution in space or, for lamps used in systems where a tell-tale indicates the failure of any one of the light sources, the light intensity in the axis of reference must be at least 50 per cent of the minimum intensity required. This collective amendment addresses Regulations Nos. 7, 23, 38, 77, 91 and 119. The proposals concerning UN R48 will be resubmitted for consideration during the 77th GRE session.
|