SLR-75-11
Rear direction indicator and stop signal visibility

The document presents OICA data on rear direction indicator (DI) and stop signal visibility compliance. It evaluates various lamp configurations against UN R48 and UN R148 requirements, examining criteria including photometry areas outside 25mm from stop lamps, DI apparent surface size, separation distances, and intensity ratios. OICA proposes that compliance requirements are met when DI apparent surface equals or exceeds stop lamp surface, intensity exceeds stop lamp by 25% minimum, separation distance reaches 20mm minimum, or DI apparent surface equals or exceeds 30cm.